Products
OEMs
About Us
Contact Us
Online Sales
iscinfo@iscsales.comSearch   My CartCart
 
Industrial Painting

For Critical Applications Where Oil is Present

  • Point of Use Dryer
  • Water Removal
  • Oil Removal
  • Oil Smoke Removal
  • Eliminate Contamination
  • Eliminate Costly Downtime

Application
RTi’s oil extractor combination units are ideal for manual or robotic industrial spray applications. Offering high volume production, low maintenance,superior finishes and ultimately contaminant free air.

Method:
Two stage patented Inverse Flow with 0.01 micron coalescing and 0.003 ppm Hydrocarbon removal with activated carbon and stainless steel mesh elements

Features
Auto drains, Differential indicators, Metal bowls, Patented elements

Above Filter available in larger sizes





Dimensions (IN):

Model Number Height Width Depth Weight (LBS)
4P-060-M02-DCi 11.5 8 3.8 9
4P-060-M03-DCi 11.5 8 3.8 9
4P-060-M04-DCi 11.5 8 3.8 9
4P-090-M04-DCi 15 10 4.6 16
4P-090-M06-DCi 15 10 4.6 16
4P-150-M08-DCi 15 10 4.6 16


Model Number Rated Flow SCFM Port Size(Inches) Drain Part Number Bowl O-Ring Number Diff. Pressure Indicator 1st Stage Element 2nd Stage Element
4P-060-M02-DCi 60 ¼ N32-95-978 N32-95-257 N32-W1-DPi 4P-060 3C-060
4P-060-M03-DCi 60 3/8 N32-95-978 N32-95-257 N32-W1-DPi 4P-060 3C-060
4P-060-M04-DCi 60 ½ N32-95-978 N32-95-257 N32-W1-DPi 4P-060 3C-060
4P-090-M04-DCi 90 ½ N32-95-978 N32-95-256 N32-W1-DPi 4P-090 3C-090
4P-090-M06-DCi 90 ¾ N32-95-978 N32-95-256 N32-W1-DPi 4P-090 3C-090
4P-150-M08-DCi 150 1 N32-95-978 N32-95-256 N32-W1-DPi 4P-150 3C-150


Standard maximum air pressure is 150 PSIG. For pressures up to 175 PSIG order unit without the “i” suffix. For applications requiring pressure vessels up to 500 PSIG, consult the factory. Rated flow is measured at inlet air pressure of 100 PSIG.

Notes:

  1. For high pressure applications from 150 to 500 psig, consult the factory.
  2. For applications where hostile chemicals are present in the environment, install only metal bowl assemblies.

Applications:
Oil Extractor Combos are to be installed as close as possible to the place where the air is to be consumed. The Oil Extractor will remove water, dirt and oil as small as 0.01 micron with 99.99998% efficiency. To extend the life of the combo units, install Eliminex Combo units in the mainline.

Installation:
Install units in a vertical position with the drains pointing downward and the air flowing in the direction indicated by the arrow on the castings. Install unit as far from the compressor as possible and as close as possible to the point of use

Service:
Do not attempt to service the unit with the air pressure in the bowls; always bleed the air from the unit prior to disassembly. Replace element when indicated by the filter change indicator or at 6 - 9 month intervals. Service the drain on a regular 3 month interval to ensure proper function and performance of the unit. This entails area cleaning/debris removed and soapy water bath of the drain.